climateprediction.net home page
Task 22004789

Task 22004789

Name wah2_eu25_s2gg_209812_13_893_012058901_0
Workunit 12058901
Created 18 Jan 2021, 19:35:20 UTC
Sent 18 Jan 2021, 22:25:44 UTC
Report deadline 1 Jan 2022, 3:45:44 UTC
Received 8 Feb 2021, 17:52:23 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 0 (0x00000000)
Computer ID 1438861
Run time 10 days 3 hours 53 min 16 sec
CPU time 9 days 19 hours 48 min 23 sec
Validate state Invalid
Credit 9,138.96
Device peak FLOPS 2.98 GFLOPS
Application version Weather At Home 2 (wah2) v8.24
windows_intelx86
Peak working set size 300.95 MB
Peak swap size 269.38 MB
Peak disk usage 200.79 MB
Stderr
<core_client_version>7.14.2</core_client_version>
<![CDATA[
<stderr_txt>
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
CPDN Monitor - Quit request from BOINC...
Signal 11 received: Segment violation
Signal 11 received: Software termination signal from kill 
Signal 11 received: Abnormal termination triggered by abort call
Signal 11 received, exiting...
18:14:58 (11424): called boinc_finish(193)
Global Worker:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=11664, iMonCtr=2
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=11424, selfPID=2156, iMonCtr=1
Model crash detected, will try to restart...
Leaving CPDN_ain::Monitor...
18:15:02 (2156): called boinc_finish(0)

</stderr_txt>
<message>
upload failure: <file_xfer_error>
  <file_name>wah2_eu25_s2gg_209812_13_893_012058901_0_r739325721_13.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
</message>
]]>
Latest Trickles Received
Time Sent (UTC) Host ID Result ID Result Name Timestep CPU Time (sec) Average (sec/TS)
03 Feb 2021 13:31:01 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 138,539 812,729 5.8664
01 Feb 2021 15:01:20 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 127,019 742,444 5.8451
31 Jan 2021 19:41:06 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 115,499 674,650 5.8412
29 Jan 2021 18:37:21 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 103,979 607,567 5.8432
28 Jan 2021 16:45:30 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 92,459 541,138 5.8527
27 Jan 2021 15:09:07 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 80,939 476,895 5.8920
26 Jan 2021 13:01:27 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 69,419 410,396 5.9119
25 Jan 2021 09:36:33 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 57,899 341,589 5.8997
23 Jan 2021 22:27:50 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 46,379 273,857 5.9048
22 Jan 2021 10:52:59 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 34,859 206,343 5.9194
21 Jan 2021 06:46:49 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 23,339 138,457 5.9324
20 Jan 2021 04:55:23 1438861 22004789 wah2_eu25_s2gg_209812_13_893_012058901_0 11,819 70,561 5.9701


©2024 climateprediction.net