climateprediction.net home page
Task 20819083

Task 20819083

Name hadcm3s_d05o_205412_120_618_011309850_0
Workunit 11309850
Created 10 Oct 2017, 18:03:49 UTC
Sent 10 Oct 2017, 18:05:11 UTC
Report deadline 22 Sep 2018, 23:25:11 UTC
Received 11 Oct 2017, 3:50:04 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 22 (0x00000016) Unknown error code
Computer ID 1443892
Run time 7 hours 48 min 17 sec
CPU time 6 hours 36 min 17 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.94 GFLOPS
Application version UK Met Office HadCM3 short v8.34
i686-pc-linux-gnu
Peak working set size 145.98 MB
Peak swap size 203.70 MB
Peak disk usage 4.50 MB
Stderr
<core_client_version>7.8.3</core_client_version>
<![CDATA[
<message>
process exited with code 22 (0x16, -234)</message>
<stderr_txt>
Signal 15 received: Software termination signal from kill 
Signal 15 received: Abnormal termination triggered by abort call
Signal 15 received, exiting...
22:47:21 (23317): called boinc_finish(193)
In boinc_exit called with status 193
Calloing set_signal_exit_code with status 193
forrtl: severe (17): syntax error in NAMELIST input, unit 5, file /more/var/lib/boinc-client/projects/climateprediction.net/hadcm3s_d05o_205412_120_618_011309850/jobs/climate.cpdc, line 396, position 20
Image              PC        Routine            Line        Source             
hadcm3s_um_8.34_i  0848A415  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  084AF3E6  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  082C77B5  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C028B  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C1E0A  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F95C9  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F867F  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  0840346D  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=607, iMonCtr=1
Model crash detected, will try to restart...
forrtl: severe (17): syntax error in NAMELIST input, unit 5, file /more/var/lib/boinc-client/projects/climateprediction.net/hadcm3s_d05o_205412_120_618_011309850/jobs/climate.cpdc, line 396, position 20
Image              PC        Routine            Line        Source             
hadcm3s_um_8.34_i  0848A415  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  084AF3E6  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  082C77B5  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C028B  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C1E0A  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F95C9  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F867F  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  0840346D  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=607, iMonCtr=1
Model crash detected, will try to restart...
forrtl: severe (17): syntax error in NAMELIST input, unit 5, file /more/var/lib/boinc-client/projects/climateprediction.net/hadcm3s_d05o_205412_120_618_011309850/jobs/climate.cpdc, line 396, position 20
Image              PC        Routine            Line        Source             
hadcm3s_um_8.34_i  0848A415  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  084AF3E6  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  082C77B5  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C028B  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C1E0A  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F95C9  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F867F  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  0840346D  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=607, iMonCtr=1
Model crash detected, will try to restart...
forrtl: severe (17): syntax error in NAMELIST input, unit 5, file /more/var/lib/boinc-client/projects/climateprediction.net/hadcm3s_d05o_205412_120_618_011309850/jobs/climate.cpdc, line 396, position 20
Image              PC        Routine            Line        Source             
hadcm3s_um_8.34_i  0848A415  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  084AF3E6  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  082C77B5  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C028B  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C1E0A  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F95C9  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F867F  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  0840346D  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=607, iMonCtr=1
Model crash detected, will try to restart...
forrtl: severe (17): syntax error in NAMELIST input, unit 5, file /more/var/lib/boinc-client/projects/climateprediction.net/hadcm3s_d05o_205412_120_618_011309850/jobs/climate.cpdc, line 396, position 20
Image              PC        Routine            Line        Source             
hadcm3s_um_8.34_i  0848A415  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  084AF3E6  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  082C77B5  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C028B  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C1E0A  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F95C9  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F867F  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  0840346D  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=607, iMonCtr=1
Model crash detected, will try to restart...
forrtl: severe (17): syntax error in NAMELIST input, unit 5, file /more/var/lib/boinc-client/projects/climateprediction.net/hadcm3s_d05o_205412_120_618_011309850/jobs/climate.cpdc, line 396, position 20
Image              PC        Routine            Line        Source             
hadcm3s_um_8.34_i  0848A415  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  084AF3E6  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  082C77B5  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C028B  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  081C1E0A  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F95C9  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  083F867F  Unknown               Unknown  Unknown
hadcm3s_um_8.34_i  0840346D  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=607, iMonCtr=1
Model crash detected, will try to restart...
Sorry, too many model crashes! :-(
Calling boinc_finish...22:49:56 (607): called boinc_finish(22)
In boinc_exit called with status 22
Calloing set_signal_exit_code with status 22

</stderr_txt>
]]>
No trickles!


©2024 climateprediction.net