climateprediction.net home page
Task 20224447

Task 20224447

Name hadcm3s_71kw_200012_168_514_010908705_0
Workunit 10908705
Created 7 Feb 2017, 22:55:26 UTC
Sent 11 Feb 2017, 4:47:20 UTC
Report deadline 24 Jan 2018, 10:07:20 UTC
Received 21 Jun 2017, 0:59:36 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 22 (0x00000016) Unknown error code
Computer ID 1383879
Run time 21 hours 36 min 16 sec
CPU time 20 hours 35 min 38 sec
Validate state Invalid
Credit 4,355.42
Device peak FLOPS 2.95 GFLOPS
Application version UK Met Office HadCM3 short v8.29
windows_intelx86
Peak working set size 164.63 MB
Peak swap size 192.73 MB
Peak disk usage 0.13 MB
Stderr
<core_client_version>7.6.22</core_client_version>
<![CDATA[
<message>
The device does not recognize the command.
 (0x16) - exit code 22 (0x16)
</message>
<stderr_txt>
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Quit request from BOINC...

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  
Sorry, too many model crashes! :-(
02:15:02 (9772): called boinc_finish(22)

</stderr_txt>
]]>
Latest Trickles Received
Time Sent (UTC) Host ID Result ID Result Name Timestep CPU Time (sec) Average (sec/TS)
07 Apr 2017 09:59:36 1383879 20224447 hadcm3s_71kw_200012_168_514_010908705_0 362,952 53,868 0.1484


©2024 climateprediction.net