Name | hadam3pm2_i0xe_1959_10_009272340_2 |
Workunit | 9365256 |
Created | 22 Jan 2015, 17:36:58 UTC |
Sent | 22 Jan 2015, 21:56:51 UTC |
Report deadline | 5 Jan 2016, 3:16:51 UTC |
Received | 24 Jan 2015, 13:12:01 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1352815 |
Run time | 5 hours 57 min 56 sec |
CPU time | 2 hours 20 min 36 sec |
Validate state | Invalid |
Credit | 168.28 |
Device peak FLOPS | 3.49 GFLOPS |
Application version | UK Met Office HadAM3P (global only) with MOSES II landsurface scheme v7.03 i686-pc-linux-gnu |
Stderr | <core_client_version>7.2.42</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234) </message> <stderr_txt> Model crashed: go Model crashed: go SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 CPDN Monitor - Quit request from BOINC... SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 SIGSEGV: segmentation violation Stack trace (13 frames): /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu(boinc_catch_signal+0x6f)[0x83bccdf] [0xf0f8e400] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x8165b39] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x816b8f8] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x8162a76] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x816d014] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x8161751] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x8085677] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x8094c0a] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x831e514] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x83205f9] /var/lib/boinc-client/projects/climateprediction.net/hadam3pm2_um_7.03_i686-pc-linux-gnu[0x834c82d] /lib/i386-linux-gnu/libc.so.6(__libc_start_main+0xf3)[0xf0d39a83] Exiting... Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=4502, iMonCtr=1 Model crash detected, will try to restart... CPDN Monitor - Quit request from BOINC... SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: go Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 SETPOS: Seek Failed: Invalid argument SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Model crashed: SETPOS: Unit 64 to Word Address -198 Failed with Error Code -1 Sorry, too many model crashes! :-( 14:38:36 (8642): called boinc_finish </stderr_txt> ]]> |
Latest Trickles Received | ||||||
---|---|---|---|---|---|---|
Time Sent (UTC) | Host ID | Result ID | Result Name | Timestep | CPU Time (sec) | Average (sec/TS) |
23 Jan 2015 02:15:13 | 1352815 | 17815391 | hadam3pm2_i0xe_1959_10_009272340_2 | 5,828 | 3,781 | 0.6488 |
23 Jan 2015 00:14:21 | 1352815 | 17815391 | hadam3pm2_i0xe_1959_10_009272340_2 | 2,948 | 7,250 | 2.4593 |