climateprediction.net home page
Task 12805508

Task 12805508

Name hadam3p_pnw_z16r_1962_1_006912859_2
Workunit 7116175
Created 21 Apr 2011, 13:19:58 UTC
Sent 21 Apr 2011, 15:55:52 UTC
Report deadline 2 Apr 2012, 21:15:52 UTC
Received 26 Apr 2011, 11:16:43 UTC
Server state Over
Outcome Didn't need
Client state Compute error
Exit status 0 (0x00000000)
Computer ID 1144957
Run time 53 min 47 sec
CPU time 42 min 34 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.12 GFLOPS
Application version UK Met Office HadAM3P-HadRM3P Pacific North West v6.09
windows_intelx86
Stderr
<core_client_version>6.10.58</core_client_version>
<![CDATA[
<stderr_txt>
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
CPDN Monitor - Quit request from BOINC...
Regional Worker:: CPDN process is not running, exiting, bRetVal = 1, checkPID=5336, selfPID=5336, iMonCtr=2
cpdnmonitor: error reading file C:\ProgramData\BOINC/projects/climateprediction.net/hadam3p_pnw_se_6.09_windows_intelx86.dll
cpdnmonitor: error reading file C:\ProgramData\BOINC/projects/climateprediction.net/hadrm3p_pnw_um_6.09_windows_intelx86.exe
forrtl: Not enough storage is available to process this command.

forrtl: severe (38): error during write, unit 8, file C:\ProgramData\BOINC\projects\climateprediction.net\hadam3p_pnw_z16r_1962_1_006912859\tmp\xaakm.pipe_dummy

Image              PC        Routine            Line        Source             
hadam3p_pnw_um_6.  0170A39A  Unknown               Unknown  Unknown
hadam3p_pnw_um_6.  016B2CD0  Unknown               Unknown  Unknown
hadam3p_pnw_um_6.  016B1E9A  Unknown               Unknown  Unknown
hadam3p_pnw_um_6.  0168183C  Unknown               Unknown  Unknown
hadam3p_pnw_um_6.  0167F65A  Unknown               Unknown  Unknown
hadam3p_pnw_um_6.  0162F29E  Unknown               Unknown  Unknown
hadam3p_pnw_um_6.  013A9BD2  Unknown               Unknown  Unknown
hadam3p_pnw_um_6.  016EE638  Unknown               Unknown  Unknown
kernel32.dll       766A1194  Unknown               Unknown  Unknown
ntdll.dll          76E2B429  Unknown               Unknown  Unknown
ntdll.dll          76E2B3FC  Unknown               Unknown  Unknown
forrtl: severe (39): error during read, unit 5, file C:\ProgramData\BOINC\projects\climateprediction.net\hadam3p_pnw_z16r_1962_1_006912859\jobs\xaakg.namelists

Image              PC        Routine            Line        Source             
hadrm3p_pnw_um_6.  0042C52A  Unknown               Unknown  Unknown
hadrm3p_pnw_um_6.  003D4460  Unknown               Unknown  Unknown
hadrm3p_pnw_um_6.  003D362A  Unknown               Unknown  Unknown
hadrm3p_pnw_um_6.  003B2469  Unknown               Unknown  Unknown
hadrm3p_pnw_um_6.  00353C95  Unknown               Unknown  Unknown
hadrm3p_pnw_um_6.  003533B2  Unknown               Unknown  Unknown
hadrm3p_pnw_um_6.  000F9860  Unknown               Unknown  Unknown
hadrm3p_pnw_um_6.  00410893  Unknown               Unknown  Unknown
kernel32.dll       766A1194  Unknown               Unknown  Unknown
ntdll.dll          76E2B429  Unknown               Unknown  Unknown
ntdll.dll          76E2B3FC  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=5868, selfPID=3500, iMonCtr=1
Model crash detected, will try to restart...
Leaving CPDN_Main::Monitor...
Regional yearly means requires 12 input files got 0
Called boinc_finish
hadam3p_pnw_z16r_1962_1_006912859/datain/ancil/ctldata/stasets/X01003279:  write error (disk full?).  Continue? (y/n/^C) 
warning:  hadam3p_pnw_z16r_1962_1_006912859/datain/ancil/ctldata/stasets/X01003279 is probably truncated
CPDN Monitor - Quit request from BOINC...

</stderr_txt>
<message>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_1.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_2.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_3.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_4.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_5.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_6.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_7.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_8.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_9.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_10.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_11.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_12.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z16r_1962_1_006912859_2_13.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>

</message>
]]>
No trickles!


©2024 climateprediction.net